1. INTRODUCTION
1.1 These Standards
define the practice of Home Inspection in the State of Arizona.
1.2 These Standards of Practice
A. provide inspection guidelines.
B. make public the services provided by private fee-paid inspectors.
BACK
TO TOP
2. PURPOSE AND SCOPE
2.1 Inspections
performed to these Standards shall provide the client with a better
understanding of the property conditions, as observed at the time of the
inspection.
2.2 Inspectors shall:
A. before the inspection report is delivered, enter into a
written agreement with the client or their authorized agent that
includes:
-
the purpose of the inspection.
-
the date of the inspection.
-
the name, address and certification
number of the inspector.
-
the fee for services.
-
a statement that the inspection is
performed in accordance with these Standards.
-
limitations or exclusions of systems
or components inspected.
B. Observe
readily accessible installed systems and components listed in these
Standards.
C. Submit a written report to the client
which shall:
-
Describe systems and components
identifiedin sections 4-12 of these Standards.
-
State which systems and components
designated for inspection in these Standards have been inspected and
any systems and components designated for inspection in these
Standards which were present at the time of the inspection and were
not inspected and a reason why they were not inspected.
-
State any systems and components
so inspected which were found to be in need of immediate major
repair and any recommendations to correct, monitor or evaluate by
appropriate persons.
2.3 These Standards are not
intended to limit inspectors from:
A. reporting observations and conditions in addition to those
required in Section 2.2.
B. excluding systems and components from the inspection if requested by
the client.
BACK TO TOP
3. GENERAL LIMITATIONS AND
EXCLUSIONS
3.1 General limitations:
A. Inspections done in accordance with these Standards are visual,
not technically exhaustive and will not identify concealed conditions or
latent defects.
B. These Standards are applicable to buildings with four or less
dwelling units and their garages or carports.
3.2 General exclusions:
A. Inspectors are NOT required to report on:
1. life expectancy of any component or
system.
2. the causes of the need for a major repair.
3. the methods, materials and costs of
corrections.
4. the suitability of the property for any
specialized use.
5. compliance or non-compliance with applicable
regulatory requirements.
6. the market value of the property or its
marketability.
7. the advisability or inadvisability of
purchase of the property.
8. any component or system which was not
observed.
9. the presence or absence of pests such as wood
damaging organisms, rodents, or insects.
10. cosmetic items, underground items, or items
not permanently installed.
B. Inspectors are NOT
required to:
1. offer warranties or guarantees of any
kind.
2. calculate the strength, adequacy, or
efficiency of any system or component.
3. enter any area or perform any procedure which
may damage the property or its components or be dangerous to the
inspector or other persons.
4. operate any system or component which is shut
down or otherwise inoperable.
5. operate any system or component which does
not respond to normal operating controls.
6. disturb insulation, move personal items,
furniture, equipment, plant life, soil, snow, ice, or debris which
obstructs access or visibility.
7. determine the presence or absence of any
suspected hazardous substance including but not limited to toxins,
fungus, molds, mold spores, carcinogens, noise, contaminants in soil,
water, and air.
8. determine the effectiveness of any system
installed to control or remove suspected hazardous substances.
9. predict future conditions, including but not
limited to failure of components.
10. project operating costs of components.
11. evaluate acoustical characteristics of any
system or component.
3.3 Limitations and exclusions
specific to individual systems are listed in following sections.
BACK TO TOP
4. SYSTEM: STRUCTURAL COMPONENTS
4.1 The inspector shall observe:
A. Structural components including:
1. foundation.
2. floors.
3. walls.
4. columns.
5. ceilings.
6. roofs.
4.2 The Inspector shall:
A. Describe the type of:
1. foundation.
2. floor structure.
3. wall structure.
4. columns.
5. ceiling structure.
6. roof structure.
B. probe structural components where
deterioration is suspected. However, probing is NOT required when
probing would damage any finished surface.
C. enter underfloor crawl spaces and attic spaces except when access is
obstructed, when entry could damage the property, or when dangerous or
adverse situations are suspected.
D. report the methods used to inspect underfloor crawl spaces and
attics.
E. report signs of water penetration into the building or signs of
abnormal or harmful condensation on building components.
BACK TO TOP
5. SYSTEM: EXTERIOR
5.1 The inspector shall observe:
A. wall cladding, flashings and trim.
B. entryway doors and representative number of windows.
C. garage door operators.
D. decks, balconies, stoops, steps, areaways, and porches including
railings.
E. eaves, soffits and fascias.
F. vegetation, grading, drainage, driveways, patios, walkways and
retaining walls with respect to their effect on the condition of the
building.
5.2 The inspector shall:
A. describe wall cladding materials.
B. operate all entryway doors and representative number of windows
including garage doors, manually or by using permanently installed
controls of any garage door operator.
C. report whether or not any garage door operator will automatically
reverse or stop when meeting reasonable resistance during closing.
5.3 The inspector is NOT
required to observe:
A. storm windows, storm doors, screening, shutters, awnings and
similar seasonal accessories.
B. fences.
C. safety glazing.
D. garage door operator remote control transmitters.
E. geological conditions.
F. soil conditions.
G. recreational facilities.
H. outbuildings other than garages and carports.
BACK TO TOP
6. SYSTEM: ROOFING
6.1 The inspector shall observe:
A. roof coverings.
B. roof drainage systems.
C. flashings.
D. skylights, chimneys and roof penetrations.
E. signs of leaks or abnormal condensation on building components.
6.2 The inspector shall:
A. describe the type of roof covering materials.
B. report the methods used to inspect roofing.
6.3 The inspector is NOT
required to:
A. walk on the roofing.
B. observe attached accessories including but not limited to solar
systems, antennae, and lightning arresters
BACK TO TOP
7. SYSTEM: PLUMBING
7.1 The inspector shall
observe:
A. interior water supply and distribution system including:
1. piping materials, including supports and
insulation.
2. fixtures and faucets.
3. functional flow.
4. leaks.
5. cross connections.
B. interior drain, waste and vent system, including:
1. traps; drain, waste, and vent piping; piping
supports and pipe insulation.
2. leaks.
3. functional drainage
C. hot water systems including:
1. water heating equipment.
2. normal operating controls.
3. automatic safety controls.
4. chimneys, flues and vents.
D. fuel storage and distribution systems including:
1. interior fuel storage equipment, supply
piping, venting and supports.
2. leaks.
E. sump pumps.
7.2 The inspector shall:
A. describe:
1. water supply and distribution piping
materials.
2. drain, waste and vent piping materials.
3. water heating equipment.
B. operate all plumbing fixtures, including their faucets and all
exterior faucets attached to the house.
7.3 The inspector is NOT
required to:
A. state the effectiveness of anti-siphon devices.
B. determine whether water supply and waste disposal systems are public
or private.
C. operate automatic safety controls.
D. operate any valve except water closet flush valves, fixture faucets
and hose faucets.
E. observe:
1. water conditioning systems.
2. fire and lawn sprinkler systems.
3. on-site water supply quantity and quality.
4. on-site waste disposal systems.
5. foundation irrigation systems.
6. spas, except as to functional flow and
functional drainage.
BACK TO TOP
8. SYSTEM: ELECTRICAL
8.1 The inspector shall observe:
A. service entrance conductors.
B. service equipment, grounding equipment, main overcurrent device, main
and distribution panels.
C. amperage and voltage ratings of the service.
D. branch circuit conductors, their overcurrent devices, and the
compatibility of their ampacities and voltages.
E. the operation of a representative number of installed lighting
fixtures, switches and receptacles located inside the house, garage, and
on its exterior walls.
F. the polarity and grounding of all receptacles within six feet of
interior plumbing fixtures and all receptacles in the garage or carport,
and on the exterior of inspected structures.
G. the operation of ground fault circuit interrupters.
8.2 The inspector shall:
A. describe:
1. Service amperage and voltage.
2. service entry conductor materials.
3. service type as being overhead or
underground.
4. location of main and distribution panels.
B. report any observed aluminum branch circuit wiring.
8.3 The inspector is NOT required
to:
A. insert any tool, probe or testing device inside the panels.
B. test or operate any overcurrent device except ground fault
interrupters.
C. dismantle any electrical device or control other than to remove
covers of the main and auxiliary distribution panels.
D. observe 1. low voltage systems.
2. smoke detectors. 3.
telephone, security, cable TV, intercoms or other ancillary wiring that
is not a part of the primary electrical distribution system.
BACK TO TOP
9. SYSTEM: HEATING
9.1 The inspector shall observe:
A. permanently installed heating systems including:
1. heating equipment.
2. normal operating controls.
3. automatic safety controls.
4. chimneys, flues and vents.
5. solid fuel heating devices.
6. heat distribution systems including fans,
pumps, ducts and piping, with supports, dampers, insulation, air
filters, registers, radiators, fan coil units, convectors.
7. the presence of an installed heat source in
each room.
9.2 The inspector shall:
A. describe:
1. energy source.
2. heating equipment and distribution type.
B. operate the systems using normal operating controls.
C. open readily openable access panels provided by the manufacturer or
installer for routine homeowner maintenance.
9.3 The inspector is NOT
required to:
A. operate heating systems when weather conditions or other
circumstances may cause equipment damage.
B. operate automatic safety controls.
D. ignite or extinguish solid fuel fires.
E. observe:
1. the interior of flues.
2. fireplace insert flue connections.
3. humidifiers.
4. electronic air filters.
5. the uniformity or adequacy of heat supply to
the various rooms.
BACK TO TOP
10. SYSTEM: CENTRAL AIR
CONDITIONING
10.1 The inspector shall
observe:
A. central air conditioning including:
1. cooling and air handling equipment.
2. normal operating controls.
B. distribution systems including:
1. fans, pumps, ducts and piping, with supports,
dampers, insulation, air filters, registers, fancoil units.
2. the presence of an installed cooling source
in each room.
10.2 The inspector
shall:
A. describe:
1. energy sources.
2. cooling equipment type.
B. operate the systems using normal operating controls.
C. open readily openable access panels provided by the manufacturer or
installer for routine homeowner maintenance.
10.3 The inspector is
NOT required to:
A. operate cooling systems when weather conditions or other
circumstances may cause equipment damage.
B. observe non-central air conditioners.
C. observe the uniformity or adequacy of cool-air supply to the various
rooms.
BACK TO TOP
11. SYSTEM: INTERIORS
11.1 The inspector shall
observe:
A. walls, ceiling and floors:
B. steps, stairways, balconies and railings.
C. counters and a representative number of cabinets.
D. a representative number of doors and windows.
E. separation walls, ceilings, and doors between a dwelling unit and an
attached garage or another dwelling unit.
F. sumps.
11.2 The inspector
shall:
A. operate a representative number of primary windows and interior
doors.
B. report signs of water penetration into the building or signs of
abnormal or harmful condensation on building components.
11.3 The inspector is
NOT required to observe:
A. paint, wallpaper and other finish treatments on the interior
walls, ceilings, and floors.
B. carpeting.
C. draperies, blinds or other window treatments.
D. household appliances.
E. recreational facilities or another dwelling unit.
BACK TO TOP
12. SYSTEM: INSULATION &
VENTILATION
12.1 The inspector shall observe:
A. insulation and vapor retarders in unfinished spaces.
B. ventilation of attics and foundation areas.
C. kitchen, bathroom, and laundry venting systems.
12.2 The inspector shall
describe:
A. insulation and vapor retarders in unfinished spaces.
B. absence of same in unfinished space at conditioned surfaces.
12.3 The inspector is NOT
required to report on:
A. concealed insulation and vapor retarders.
B. venting equipment which is integral with household appliances.
BACK TO TOP